TFM Insight Helium / Hydrogen Leak Detector

Insight Helium / Hydrogen Leak Detector
Overview
Accessory Recommendations
Overview
Applications
- Research & Development
The system is ideal for research environments, supporting cutting-edge innovations and new material testing. - Analytical Research and Instrumentation
Used in laboratories for precise measurement and analysis, ensuring accurate data collection in various scientific applications. - Vacuum Components
Widely utilized in the vacuum industry, the system is integrated into components that demand high-performance vacuum levels for optimal operation. - Electronics
In the electronics sector, it helps in producing and testing sensitive electronic devices, contributing to enhanced product reliability. - Automotive
Supports the automotive industry through precise measurement systems that assist in the development of more efficient and reliable vehicle components.
Features
- High-Performance System
Delivers top-tier performance, ensuring that even the most demanding applications can be handled efficiently. - Proven Measurement System with Exceptional Reliability
Built on a foundation of dependable technology, the system provides accurate, repeatable results, enhancing productivity and confidence in the data. - Fast Helium Pumping Speed for Accurate Measurements
With a high helium pumping speed, the system ensures that measurements are completed quickly and with precision, improving overall workflow. - User-Friendly Digital Display
The built-in digital display is easy to navigate, making operations smooth and intuitive. The system also supports additional connectivity options with RS-232 and RS-485 ports for extended functionality. - Compact and Versatile Design
The compact form factor makes it adaptable to various environments, offering flexibility for both space-constrained setups and more extensive systems. - Durable Ion Source with Long-Life Iridium Filaments
Equipped with two yttrium-oxide coated iridium filaments, the ion source boasts an extended lifespan and comes with a 3-year warranty, ensuring long-term reliable performance.
Specifications Table
Leak Detector Model | Insight W | Insight D | Insight N |
---|---|---|---|
Backing Pump | Wet | Dry | No Backing Pump |
Pumping Speed | He 3.00 L/s Rough 3.40 CFM 5.80 m3/hr | He 3.00 L/s Rough 1.20 CFM 2.04 m3/hr | He 3.00 L/s No Backing Pump |
Run Up Time | < 180 seconds | < 180 seconds | < 180 seconds |
Detectable Masses AMU | 2, 3, 4 | 2, 3, 4 | 2, 3, 4 |
Mass Spectrometer | 180° Magnetic Sector Field | 180° Magnetic Sector Field | 180° Magnetic Sector Field |
Ion Source | Two yttrium/irridum long life filaments | Two yttrium/irridum long life filaments | Two yttrium/irridum long life filaments |
Inlet Flange | KF25 | KF25 | KF25 |
Smallest Detectable Leak Rate | Helium Vacuum Operation < 5 x 10-12 mbar*L/s Helium Sniffer Mode < 5 x 10-8 mbar*L/s Hydrogen Vacuum Operation < 5 x 10-8 mbar*L/s Hydrogen Sniffer Mode < 5 x 10-8 mbar*L/s | Helium Vacuum Operation < 5 x 10-12 mbar*L/s Helium Sniffer Mode < 5 x 10-8 mbar*L/s Hydrogen Vacuum Operation < 5 x 10-8 mbar*L/s Hydrogen Sniffer Mode < 5 x 10-8 mbar*L/s | Helium Vacuum Operation < 5 x 10-12 mbar*L/s Helium Sniffer Mode < 5 x 10-8 mbar*L/s Hydrogen Vacuum Operation < 5 x 10-8 mbar*L/s Hydrogen Sniffer Mode < 5 x 10-8 mbar*L/s |
Units of Measurement | Pressure mbar Pa atm Torr Leak Rate mbar*L/s Pa*m^3/s Torr*L/s atm*cc/s sccm | Pressure mbar Pa atm Torr Leak Rate mbar*L/s Pa*m^3/s Torr*L/s atm*cc/s sccm | Pressure mbar Pa atm Torr Leak Rate mbar*L/s Pa*m^3/s Torr*L/s atm*cc/s sccm |
Time Constant | Leak Signal < 0.50 seconds | Leak Signal < 0.50 seconds | Leak Signal < 0.50 seconds |
Inlet Pressure | max 18.0 mbar 1800 Pa 18.0 hPA 13.5 Torr | max 18.0 mbar 1800 Pa 18.0 hPA 13.5 Torr | max 18.0 mbar 1800 Pa 18.0 hPA 13.5 Torr |
Dimensions in. (mm.) | 21.9 x 12.0 x 16.8 ( 555 x 305 x 425 ) | 21.9 x 12.0 x 16.8 ( 555 x 305 x 425 ) | 21.9 x 12.0 x 16.8 ( 555 x 305 x 425 ) |
Weight Lbs (kg) | 93.0 ( 42.0 ) | 90.0 ( 41.0 ) | 71.0 ( 32.0 ) |
Accessory Recommendations
Product | Description | Suggested Part Number | Components Needed |
---|---|---|---|
Inlet Filter (Suggested) | Inlet filters help remove unwanted particulates or contaminates from entering the leak detector. Common filters are rated down to 10 um. Inlet Filters are sold separately for the KJLC Insight Helium Leak Detector. | Straight Style: LDA-KJLC-S-2KF25 “L” Style: LDA-KJLC-L-2KF25 “T” Style: LDA-KJLC-T-3KF40 | Inlet Filter; O-rings and clamps are included with the filter. |
Sniffer Line (Suggested) | Allows for leak detection via the sniffing method. Simply put, this method is used when you fill a vessel with helium and use the “sniffer” to determine if helium is leaking out. Sniffer lines are sold separately from the KJLC Insight Helium Leak Detector. | 3 Meter: LDA-KJLC-SFR3 5 Meter: LDA-KJLC-SFR5 10 Meter: LDA-KJLC-SFR10 | Sniffer Line; standard sniffer tip included. |
Remote Control (Suggested) | Allows the KJLC Insight Helium Leak Detector to be operated remotely, whether wired or wireless. Remote controllers are sold separately from the Leak Detector. | Wired: LDA-KJLC-RCC Wireless: LDA-KJLC-RCW | Either wired or wireless remote controller. |
Power Supply (Included) | Standard power supply to power the KJLC Insight Helium Leak Detector. | — | Power cable included with KJLC Insight Helium Leak Detector. |